Skip to content

Respirator Fit-Testing Methods (ANSI/AIHA/ASSE Z88.10-2010)

“A standard for carrying out the proper way to carry out fit testing was long overdue and has been immensely helpful in the field of respiratory protection. At OHD, we commend those who further our mission of protecting the world’s workforce.” Dr. Stephanie Lynch, PhD (Product Manager), OHD, LLLP, 205.980.0180, www.ohdglobal.com.

History

Developed by ANSI (now known as ASSP), with content provided by the American Society of Safety Engineers (ASSE), guideline Z88.10-2010 provides respiratory protection program managers (RPPM) with clear, consistent guidance on respirator fit-testing and the components required of an effective respiratory protection program. Included in the guide are instructions on how to avoid interference of PPE; it also provides detailed information on face pieces, including their selection, and other considerations for effective fit-testing. Z88.10 was last updated in 2010.

Qualitative fit-testing is a pass/fail test that uses the wearer’s sense of taste or smell, or his reaction to an irritant, in order to detect leakage into the respirator facepiece. Whether or not a worker needs a full-face respirator or a half-mask respirator depends on the Assigned Protection Factor (APF). The APF is a number that describes the level of protection that a respirator can be expected to provide—if used properly.

Yearly fit-testing is now required. According to OSHA, an employer that performed fit-testing every two years reported 7% of their employees switched to different respirator sizes and/or models each time they were tested. OSHA considered this 7% measurement to be unacceptable and adopted the policy to require annual fit-testing and training.

Why Standard is Important

Fit-testing is a protocol used to evaluate sealing surface leakage of a specific, tight-fitting respirator while it is being worn. Individuals do not have to be issued the same respirator that they are fit-tested with, as long as they are issued a respirator that is the same make, model, style, size and material of respirator with which they are fit-tested. There are two categories of respirator fit-testing, which include qualitative and quantitative fit-testing methods.

Standard Z88.10 provides in-depth requirements for training fit-test operators; it also includes a large section entitled “General Considerations,” which covers in detail the important considerations for performing all respirator fit-testing protocols.

Clause 6 of the General Considerations section includes medical evaluation and pre-fit test training (such as how to don the respirator without assistance).  Z88.10 recommends using a mirror to see how to position and adjust the respirator, for example. Also in this section are guidelines on how to inspect the respirator and how to accomplish user seal checks.

Key Compliance Requirements

There are numerous factors that could potentially diminish the effectiveness and fit of a respirator. These include:

  • Weight gain or loss
  • Dental work or facial surgery
  • Significant scarring in areas where seal meets skin
  • Wearer discomfort
  • Facial hair or certain hair styles
  • Cosmetics or facial jewelry
  • Glasses or protective eyewear
  • Do not perform fit testing if any foreign material, like gels or creams, are present between the sealing surfaces of the face and the respirator
  • PPE must not interfere with respirator sealing surfaces and must be worn during fit testing

In addition, there are some other conditions that can adversely affect fit. These include possible facial feature interference, such as hollow temples, exceedingly protruding cheekbones, deep skin creases, absence of teeth or dentures, or facial injury including mouth or facial swelling.

If dentures are worn during respirator use, dentures should be worn during fit-
testing. If dentures are not worn during respirator use, then dentures should not be worn during fit-testing. WMHS

Resources:

Share on Socials!

Related Articles

Related Articles

The Right Stuff: Finding the Proper Welding Safety PPE

Andrew Ortman, Contributor This article takes a deep look into the safety products all welders should be wearing and the options that they have. By breaking ...
Read More

Control of Hazardous Energy (Lockout/Tagout) General Industry – Regulation 29 CFR 1910.147

Enforcement from Oct. 2021-Sept. 2022 Total citations: 2,129 Total inspections: 1,170 Total proposed penalties: $14,812,924 Most Frequently Violated OSHA Standard Ranking – Number 6 Industries most ...
Read More

New HEAVYDUTY 20 Anti-Slip Coating Is Ideal for Industrial and Commercial Environments

Wooster Products introduces HEAVYDUTY 20, an anti-slip coating which provide high traction and durability for industrial areas including factories and manufacturing environments, as well as industrial ...
Read More

Follow WMHS!

Workplace

Construction
Ind Hygiene

 

Scroll To Top